1-50MW Microgrid Hybrid Power Plant

 

 Global Leader In Distributed Solar Hybrid Solutions& Off-Grid Systems.

Sites: Qty. 4
Total Power Installation: 6MW
Each Site: Diesel Generators 2 units of 500kW & 2 units of 250kW

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Product Description
Design Standards

 

Diesel Generators® Each site is equipped with totally 4 units of diesel generators (2 units of 500kW and 2 units of 250kW) as backup power,  to coordinate with PV panels and BESS.

SCADA® each site can run the SCADA independently and communicate with master system in realtime. StarLink for communication backup. Realtime data and remote control. Weather forecasting for emergency response.

 

 

Scene Diagram

 

Explainer Video

 

Benefits

1. Stabilize the power supply by weather analyzing and forecasting, and adjust the power deployment.
2. Analyze and manage the loads, working state of PV and the BESS, to maximize fuel efficiency of diesel generators.
3. Independently and flexibly adjust the operating status and distribution of power generation and loads to maximize the operatingefficiency;
4. Have the ability to form a large power grid with other microgrid (HV power grid / LV power grid). Each site can communicate with
each other and the master system.
5.MPMC Self developed SCADA supports realtime remote monitoring and control,alarms and faults management and setting of all equipments, history records management, etc.

Features

Input

fixed

value

Meteorolog

ical

data

Photovoltaic

data

 

Battery data

 

PCS data

 

HVAC data

Fireproof

system data

 

Genset data

 

Other

accessories

status

 

 

 

Input

 

Estimated

annual peak

load; Air

conditioner

temperature

setting;

Manual fire

sprinkler

trigger;

Manual

switch of

equipment

 

 

Light

intensity;

Severe

weather

warning

 

 

Real-time

operating

data and

fault

alarms *

detail in the

communication

protocol

Pack/cluster/

stack voltage;

Pack/cluster/

stack current;

Pack/cluster

temperature;

Pack/cluster/

stack SOC; 

Cluster SOH;

Protecting 

pack from:

Overvoltage/

undervoltage,

overcurre nt,

short

circuit,high/low

temperature;

Protecting

cluster from:

Overcurrent,

overdischarge,

high 

temperature,

overcharge;

Protecting

stack from:

overvoltage/

undervoltage,

overcurre nt,

short

circuit,high/low

temperature;

Internal 

Fault detection;

Communication 

Fault detection

 

 

Real-time

operating 

data and

fault alarms *

detail in the

communication

protocol

 

 

Real time

power;

Real time

Temperature;

Operating

status; 

Fault alarm

 

 

Smoke

detection;

Temperature

check;

Operating

status; 

Fault alarm

 

 

Real-time

operating data

and fault

alarms *

detail in the

communication

protocol

 

STS all

information

in the

communication

protocol;

Opening/

closing status

and protection

alarm of system

circuit breaker;

Transformer

protection

alarm;

Power

environment

tracker;Server

running status;

Oil pump

running

status; Mailbox

liquid

level status

Processing

Unit

SCADA-

Switch-

PLC

Switch-   

PLC/

SCADA

Switch-

PLC/

SCADA- 

EMS

Switch-PLC/

SCADA-EMS

Switch-

PLC/

SCADA-

EMS

Switch-

SCADA

Switch-

SCADA

Switch-

PLC/

SCADA-

EMS

Switch-SCADA

 

 

 

Output

 

 

 

Light

intensity;

Severe

weather 

warning

 

 

Real-time 

operating

data and fault

alarms *

detail in the

communication 

protocol

pack/cluster/

stack voltage;

pack/cluster/

stack current;

pack/cluster

temperature;

pack/cluster/

stack SOC;

Cluster SOH;

Protecting 

pack from:

Overvoltage/

undervoltage,

overcurre nt,

short

circuit,high/low

temperature;

Protecting

cluster from:

Overcurrent,

overdischarge,

high 

temperature,

overcharge;

Protecting

stack from:

overvoltage/

undervoltage,

overcurre nt,

short

circuit,high/low

temperature;

Internal Fault

detection;

Communication 

Fault detection

 

 

Real-time

operating

data and

fault alarms *

detail in the
communication

protocol

 

 

Real time

power;

Real time

Temperature;

Operating

status; 

Fault alarm

 

 

Smoke

detection;

Temperature

check;

Operating

status; 

Fault alarm

 

 

Real-time

operatin

data and

fault alarms *

detail in the

communication

protocol

 

STS all 

information

in the

communication

protocol;

Opening/

closing

status and

protection

alarm

of system

circuit breaker;

Transformer

protection

alarm;

Power

environment

tracker;

Server running

status; Oil pump 

running status; 

Mailbox liquid 

level status

Additional

Settings

 

 

 

 

 

 

 

 

 

Product Picture

 

Basic Logic

 

 

Product Details

 

  • LFP battery ack system
  • Brand generator et
  • AC output cabinet
  • Tansformer
  • Large access to control panel and see-through window.
  • EMS control system
  • Stainless steel door locks.
  • Dedicated Lifting Rings 

CONTACT US